Model TVB200-Plus
10
3. Operation
Upon plugging in the power, the unit performs a self-test and selects
the video input that was previously selected. If the unit was in “Auto”
mode prior to shut down, then it will come up in auto mode. To select
an input, simply press the push-button on the front of the unit
corresponding to that input. Corresponding LED indicates the selected
input.
Alternatively, the TVB200-Plus can be controlled by the serial RS232
port from any computer or RS-232 device (see details in following
section).
If the VGA input is selected, then the unit buffers the signal and passes
it to the output without modification. If the input is from one of the 3
NTSC or PAL channels, the unit automatically converts the signal to
VGA. The conversion is performed by line doubling and image
processing via digital filtering. The output signal preserves the entire
information contained in the TV input signal, and also improves the
way it appears on the screen by line doubling (de-interlaced). The
output resolution during conversion is 640x480 for NTSC Systems and
768x576 for PAL. Almost all VGA monitors and LCD's today should
automatically size the image to perfectly fit the screen.
Some VCR's (particularly lower cost ones with no time-base
correction), may not output accurate and clean video signal timing
Figure 2.2
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Kommentare zu diesen Handbüchern